Lead the sensor cable (red) and the limiter cable (white) through the drilled hole and connect both cables to the main relay box as advised on pages 18-19. 4. Connect the sensor cable to the sensor board according to ! g. Make sure the connections are correct. Connect the limiter cable (2-core white cable) to the limiter board (STB). 5. Mount the sensor to the ceiling plank using two supplied screws and attach the housing cover. 6. After completed installation and correct commissioning of the control unit, the sensor line for overheating protection must be tested for proper functioning. Disconnect one of the wires of the white cable at the STB board in the sensor housing – the respective error messag